Basic Info.
Model NO.
dt-Diesel generating set
Type
Silent Generator Set
Output Type
AC Three Phase
Usage
Common Units, Standby Unit, Emergency Crew
Excitation Mode
AC Rotating Exciter
Fuel Consumption
216g/Kw.H
Transport Package
Wooden Case
Specification
2300MM*1060MM*1300
Product Description
TECHNICAL DATADATA | DTC66 |
GENERATOR | Frequency (HZ) | 50HZ |
Rated Power | 48KW/60KVA |
Standby Power | 52.8KW/66KVA |
Rated AC Voltage(V) | OPTIONAL |
Speed | 1500RPM/1800RPM |
Aspiration | Natural Aspiration |
Starting System | Electric start with battery |
Fuel Tank Capacity (L) | 8-12 hours fuel tank |
Compression | 16.5:1 |
ENGINE | Engine Model | 4BTA3.9-G2 |
Cylinder | 4 |
Bore×Stroke | 102*120 |
Fuel Consumption(g/kw/h) | 216 |
Displacement | 3.9L |
Combustion System | Direct Injection |
ALTERNATOR | Alternator Model | DT-TWG |
Alternator Type | brushless,three phase,224E |
OPTIONAL FEATURES | Earth Leakage | OPTIONAL |
Hour meter | OPTIONAL |
Current meter | OPTIONAL |
ATS | OPTIONAL |
DIMENSIONS | Dimention(LxWxH)(mm) | 1850*800*1400 |
Net Weight(kgs) | 1480KGS |
1. Selection of common generator sets.
The common generator set has a long working time, the load curve changes greatly, the unit capacity, the number of units, the type selection and the unit control mode are different from the emergency unit. (1) capacity determination: according to the long-term continuous operation of the unit output power can meet the maximum calculation load selection of the whole project, and according to the importance of the load to determine the spare capacity of the generator set. The continuous output power of diesel engine is generally 0.9 times of the nominal power. (2) determination of the number of sets: generally more than 2 sets are set to ensure the continuity of power supply and adapt to the change of power load curve. Only when the number of units is large can the number of units put into the generator set be determined according to the change of power load, so that the diesel engine is often operated under economic load, so as to reduce the fuel consumption rate and power generation cost. The optimum economical operation condition of diesel engine is between 75% and 90% of the nominal power. In order to ensure the continuity of power supply, standby units should be set up in common units themselves. (3) determination of the speed: the general civil should choose the speed of 1000 ~ 1500 RPM high speed unit, and the speed of 300 ~ 350 RPM low speed unit is suitable for Marine host. (4) determination of voltage: the output voltage of the generator is determined as the same as that of the emergency generator set, which is generally 400V. Some projects with large power consumption and long transmission distance can choose the high-voltage generator set.
2. Selection of spare generator set.
When the sum of load capacity is multiplied by the required coefficient, and the calculated load is less than the capacity of the emergency diesel generator set, the standby coefficient shall be considered as 1.2, that is, 1.2 times the calculated capacity is less than the capacity of the emergency diesel generator set, and the emergency generator set shall supply power to the load after the power failure. When the sum of load capacity is multiplied by the required coefficient and the calculated load is greater than the capacity of a single emergency diesel generator set, two automatic generator sets with the same type, capacity, voltage regulation and speed regulation characteristics can be selected. One or two units shall supply power to the domestic and commercial electricity after the power failure of the utility; When the city power failure, and a fire, by 2 units to the fire load power supply, to facilitate fire.
3. Selection of emergency generator.
In general, emergency generators should be of high speed, high pressure, low fuel consumption and the same capacity. The single engine of high speed supercharged diesel engine has larger capacity and occupies less space. The diesel engine is equipped with electronic or hydraulic speed regulating device. Generator should be equipped with brushless excitation or phase compound device of synchronous motor, more reliable, low failure rate, more convenient maintenance; When the capacity of a single air-conditioner or motor is large in the first stage load, it is advisable to choose the generator set with third-harmonic excitation. The unit is mounted on a common chassis with shock absorber; A muffler should be installed at the outlet of the exhaust pipe to reduce the impact of noise on the surrounding environment. (1) capacity determination: the emergency generator set is used for emergency, often in standby emergency starting state, the continuous running time is not long, generally not more than 8h, so the capacity can be determined by the "standby power". The capacity of the emergency diesel generator set is determined according to the sum of the capacity of the primary load (excluding the spare capacity), considering the capacity of the corrected unit and meeting the starting requirements of the largest motor in the primary load. Three-phase ac synchronous generators are generally selected for emergency generators, and their calibrated output voltage is 400V. (2) the number of sets: the general selection of 1 set of automation, speed 1000 ~ 1500 r/min, brushless excitation, 400/230v, three-phase four-wire control panel, charging and discharging equipment and common chassis generator set. Common chassis with daily fuel tank may be required to reduce piping and footprint. In addition, in terms of reliability, 2 units can also be selected to supply power in parallel. The number of generators for emergency use should not exceed 3. When multiple units are selected, the units shall try to select complete sets of equipment with the same model, same capacity, similar characteristics of pressure regulation and speed regulation, and the nature of fuel used shall be consistent so as to facilitate maintenance and sharing of spare parts.
PRODUCING LINE
OVERSEAS MARKET
OUR TEAM
COMPANY INTRODUCTION FUJIAN DT ELECTRICAL MACHINE CO.,LTD was founded in 2005, which is located in Qinxiyang industrial area, in China most famous electrical and machine city--Fuan. With the development of more than 10 years, the total assets have reached the amount of more than 5,000,000USD, and the area of factory is more than 20,000m2. At present, the to-tal employee is more than 350, among which 25 members are seniorengineers. In 2014, the total output value has reached 80,000,000RMB. Our company has become the major enterprise in the line of electrical products in Fuan city. Our company is a private enterprise which is engaged in scientific, research, producing, import and export. The major products are including Alternators, Generators sets, Electric Motor, Water pumps and accessories of them. Our company has rich technical forse, advanced producing line and testing equipment.CONTACT MEFAQ
1. What is the quality warranty?
We gurantee one year since bl date, and offer best after selling service forever.
2. What is the delivery time?
General speaking 30-45days.
3. Do you make inspection before shipping?
Yes, of course. We have two groups of inspectors to check carefully.
4. Are you a factory?
Yes, we are a professional manufacturer.
Address:
NO. 10 XITAI ROAD, BANZHONG VILLAGE, FUAN, FUJIAN, CHINA
Business Type:
Trading Company
Business Range:
Electrical & Electronics, Industrial Equipment & Components
Company Introduction:
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.